3000 Series Model List File Contents
File Text Summary
To view the full, formatted text, download the file above
Bennett 3000 Series
Model List
Effective Date: January 1, 2010 Replaces: July 1, 2008
3000 is a chassis platform common to all Bennett single and dual dispensers and suction pumps. It includes many styles of dispensers, both mechanical an electronic, in high hose and low hose styling, with a wide range of flow rates. 3000 series is also sometimes referred to as the 3K Series. Commercial (Volume Only Displays) Models Retail (Money & Volume Displays) Models Mechanical Models Electronic Models Low Hose Style Models High Hose Style Models Conventional Flow Rate Models Little Squirt 40gpm Electronic Models Big Squirt 60gpm Electronic Models Satellites (3K series & LPS Economy series) Accessories Freight Terms In USA: Title to goods transfers at our shipping dock in Spring Lake, Michigan. Freight is prepaid and allowed to one destination within continental USA. Freight Charges In USA (Divided by the Mississippi River): Eastern USA: $75 Western USA: $100 Freight Terms International: Title to goods transfers at our shipping dock in Spring Lake, Michigan Freight is prepaid and allowed to any port in continental USA For additional details regarding freight and title transfer, refer to Policy Manual.
3000 Series Model List
Bennett 1218 E. Pontaluna Road, Spring Lake, MI 49456 USA 800-235-7618 Outside USA 231-798-1310 sales@bennettpump.com
Effective January 1, 2010
www.bennettpump.com
Table of Contents
3K Series Model List, Effective November 6, 2009
Description Commercial Suction Pumps & Remote Dispensers (Volume Only Displays) Fleetmaster Low Hose Mechanical & Options GoPump Low Hose Electronic & Options (Conventional Flow Rates) GoPump High Hose Electronic & Options (Conventional Flow Rates) Little Squirt Low Hose Electronic & Options (40gpm Nominal Flow Rates) Big Squirt Low Hose Electronic & Options (60gpm Nominal Flow Rates) Big Squirt High Hose Electronic & Options (60gpm Nominal Flow Rates) Retail Suction Pumps & Remote Dispensers (Money & Volume Displays) Heritage Low Hose Mechanical & Options GoPump Low Hose Electronic & Options (Conventional Flow Rates) GoPump High Hose Electronic & Options (Conventional Flow Rates) Little Squirt Low Hose Electronic & Options (40gpm Nominal Flow Rates) Big Squirt Low Hose Electronic & Options (60gpm Nominal Flow Rates) Big Squirt High Hose Electronic & Options (60gpm Nominal Flow Rates) Satellites and Satellite Options Accessories (Hoses, Swivels, Etc.)
Page 3,4 5,6 7,8 9,10 11,12 13,14
15,16 17,18 19,20 21,22 23,24 25,26 27,28 29
While it is not required that you do so, this booklet is designed to be printed on front and back of each sheet. Printing on front and back will ensure that each dispenser Model sheet page has it's options printed on the back of the sheet. Each model number references a configuration drawing key. These drawings provide a quick visual reference of a front and rear view of the dispenser that shows meters, pumping units (if a suction pump), nozzle boot orientation, high or low hose style design, the location of the displays, etc. A separate document contains all the configuration drawings. An example is shown at right for a 1Product, 2-Hose Dual Suction Pump with side mount nozzle boots.
Second drawing is always the rear
5
First drawing is always the front
3000 Series Model List
2
Effective January 1, 2010
Fleetmaster Commercial (Volume Only) Mechanical Dispensers Low Hose Style Cabinets
Nozzle Boot Mount Nominal Flow Rate in GPM (note 1) Suction / Remote Electric Reset Models 1 or 2 Sided Base Drawing # P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1389s1v1 P1389s1v2 P1389s1v1 P0349 P0349 CamAc Models Pumping Units Product Inlets Cabinet Style Hose Outlets Drawing Key 66
Description
Suction Pumps Single Single-HD 1Prod Dual 2Prod Dual 2Prod Dual-HD 3111SNS-66 3111HNS-66 3112SNS-5 3122SNS-11 3122HNS-11 3211SNS-66 Suction 3211HNS-66 Suction 3212SNS-5 Suction 3222SNS-11 Suction 3222HNS-11 Suction 1 1 1 2 2 1 1 2 2 2 Low Low Low Low Low 2 2 2 2 2 Side Side Side Side Side Standard 15 24 23 & 13 (Note 2) 15 24 HeavyDuty 66 HeavyDuty 5 Standard 11
HeavyDuty 11
Remote Dispensers Single 1Prod Dual 2Prod Dual Single Satellite Dual Satellite 3111SNR-68 3112SNR-21 3122SNR-27 LPS40-1-65 LPS40-2-65 3211SNR-68 Remote 1 3212SNR-21 Remote 1 3222SNR-27 Remote 2 LPS40-1-65 Remote 1 LPS40-2-65 Remote 2 1 2 2 1 2 Low Low Low Low Low 2 2 2 1 2 Side Side Side Either Either 68 21 27 65 65 23 23 23
Note 1: Flow rates are nominal rates under test conditions. Actual rates will vary subject to installation conditions, hanging hardware used, and submerged pump used if applicable. Rates are in U.S. gallons per minute. For liters per minute multiply gpm X 3.7854. Note 2: One Product, Dual Suction Flow Rate: First GPM number is rate with only 1 hose flowing. Second GPM number is rate from each hose with both hoses flowing simultaneously. Note 3: For freight and title transfer information, refer to your Distributor Policy & Procedure Manual.
Model List: Fleetmaster Low 3000 - 110609
3000 Series Model List
3
Effective January 1, 2010
Fleetmaster Commercial (Volume Only) Mechanical Dispensers Low Hose Style Cabinets OPTIONS
Add desired option(s) to end of Cabinet model number, for example, 3112SNS-5-E85-P10-SD-SE Option V E85 IG L 11550 23060 23050 380 P10 P100 J 2C HR WD BD KD GD YD OD SD SE AP SS STR SK SO NK CG SP GD Note 1: Descriptions Solenoid valve option. For 1-Product,1-Hose Suction or 2-Product, 2-Hose Suction. Standard on other models. E85 Compatibility Imperial Gallon measurement. US Gallons is standard. Liter measurement. US Gallons is standard. 115v 50Hz. 115v60Hz is standard. 230v60Hz. 115v60Hz is standard. 230v50Hz. 115v60Hz is standard. 380v50Hz 3-Phase. 115v60Hz is standard. 10:1 Gallon Pulser 100:1 Gallon Pulser Junction Box in Lower Hydraulic Area. Standard is wiring terminal strip in electronics head. 2nd field conduit. One 3/4" field conduit is standard. If Pulse Output is selected (P or P2) a second conduit is automatically added at no charge. Hose Retractor (internal); (low hose models only) - Hose Clamp is NOT Included. White lower doors. Red is standard. Blue lower doors. Red is standard Black lower doors. Red is standard. Green lower doors. Red is standard. Yellow lower doors. Red is standard. Above are standard Bennett colors. For Other color lower door single color or special screening, provide artwork. Brushed Stainless lower door. Red is standard. Brushed Stainless End Panel. Black painted is standard. Stainless "All Panels" Option (combines SD & SE & top of display compartment) "Super Stainless" Option. Combines AP plus hinged upper doors. Strainer for remote dispensers. Internal paper filter cartridge is standard. Strainer with cloth sack for remote or suction dispensers. Internal paper filter cartridge is standard for remotes; Strainer is standard for suction models. Spin-On Filter for remote models. Internal paper filter cartridge is standard. Includes 10micron standard filter & filter adapter. Nozzle Kit (field installed) for Balance Vapor Nozzle (Kit #A601801) Custom Graphics, One Time Charge Per Color Special Paint, One Time Charge per Color New Graphics Design Services. Rate per Hour (1-Hr Minimum) Standard 10micron spin on is compatible with E85 Note 1 Notes
Bennett Pump Company / Bennett Commercial Pump Company Model List: Fleetmaster Low Options - 070108 Replaces: November 19, 2007
3000 Series Model List
4
Effective January 1, 2010
GoPump Commercial (Volume Only) Electronic Dispensers Low Hose Style Cabinets
Nozzle Boot Mount Nominal Flow Rate in GPM (note 1) Low Hose Models Suction / Remote 1 or 2 Sided Fleet Card Option Available? yes yes yes yes no no no no no no no Base Drawing # P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1387s2v4 P1385s2v4 P1385s2v4 P1385s2v4 P0349 P0349 Pumping Units Product Inlets Cabinet Style Hose Outlets Drawing Key 1 2 1 2 5 6 7 11 12 13 11 12 13 33
Description
Single Single Single-HD Single-HD 1Prod Dual 1Prod Dual 1Prod Dual 2Prod Dual 2Prod Dual 2Prod Dual 2Prod Dual-HD 2Prod Dual-HD 2Prod Dual-HD Active-4
3711SNS-1 -2 3711HNS-1 -2
Suction Pumps - Low Hose Style Cabinets Suction 1 1 Low 2 Side Standard Suction 1 1 Low 1 Front Standard Suction 1 1 Low 2 Side Heavy Duty Suction 1 1 Low 1 Front Heavy Duty 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 4 Low Low Low Low Low Low Low Low Low Low 2 2 1 2 1 2 2 1 2 2 Side Front Front Side Front Front Side Front Front Front Heavy Duty Heavy Duty Heavy Duty Standard Standard Standard Heavy Duty Heavy Duty Heavy Duty Heavy Duty
15 15 24 24 23 & 13 (Note 2) 23 & 13 (Note 2) 23 & 13 (Note 2) 15 15 15 24 24 24 23 & 13 (Note 2)
3712SNS-5 Suction -6 Suction -7 Suction 3722SNS-11 -12 -13 3722HNS-11 -12 -13 Suction Suction Suction Suction Suction Suction
P1388s2v3 no P1388s2v3 yes P1388s2v3 no P1388s2v3 no P1388s2v3 no P1388s2v3 yes P1388s2v3 no P1388s2v3 no P1388s2v3 yes
3724SNS-33 Suction
Single Single 1Prod Dual 1Prod Dual 1Prod Dual 2Prod Dual 2Prod Dual 2Prod Dual Active-4 Single Satellite 3K Dual Satellite 3K Dual Satellite 3K Single Satellite Dual Satellite
Remote Dispensers - Low Hose Style Cabinets Side 17 3711SNR-17 Remote 1 1 Low 2 -18 Remote 1 1 Low 1 Front 18 3712SNR-21 Remote -22 Remote -23 Remote 3722SNR-27 Remote -28 Remote -29 Remote 3724SNR-35 Remote 3811LSR-59 Remote 3822LSR-61 Remote -62 Remote LPS40-1-65 Remote LPS40-2-65 Remote 1 1 1 2 2 2 2 1 2 2 1 2 2 2 2 2 2 2 4 1 2 2 1 2 Low Low Low Low Low Low Low Low Low Low Low Low 2 2 1 2 1 2 2 1 2 1 1 2 Side Front Front Side Front Front Front Front Front Front Either Either 21 22 23 27 28 29 35 59 61 62 65 65
23 23 23 23 23 23 23 23 23 & 13 (Note 2)
P1389s1v1 yes P1389s1v1 yes P1389s1v2 no P1389s1v2 yes P1389s1v2 no P1389s1v1 no P1389s1v1 no P1389s1v1 yes
Note 1: Flow rates are nominal rates under test conditions. Actual rates will vary subject to installation conditions, hanging hardware used, and submerged pump used if applicable. Rates are in U.S. gallons per minute. For liters per minute multiply gpm X 3.7854. Note 2: One Product, Dual Suction Flow Rate: First GPM number is rate with only 1 hose flowing. Second GPM number is rate from each hose with both hoses flowing simultaneously. Note 3: For freight and title transfer information, refer to your Distributor Policy & Procedure Manual.
Model List: GoPump-C-Low 3000 - 070108
3000 Series Model List
5
Effective January 1, 2010
GoPump Commercial (Volume Only) Electronic Dispensers Low Hose Style Cabinets OPTIONS
Add desired option(s) to end of Cabinet model number, for example, 3711SNS-2-V-P Option SL V E85 IG L M 11550 23060 23050 380 P P2 F J 2C R HR WD BD KD GD YD OD SD SE AP SS STR SK SO Descriptions Satellite-in-use Light for Master hose (remotes only) Solenoid valve option. For 1-Product,1-Hose Suction or 2-Product, 2-Hose Suction. Standard on other models. E85 Compatibility Imperial Gallon measurement. US Gallons is standard. Liter measurement. US Gallons is standard. Mechanical Calibration. Electronic calibration is standard. 115v 50Hz. 115v60Hz is standard. 230v60Hz. 115v60Hz is standard. 230v50Hz. 115v60Hz is standard. 380v50Hz 3-Phase. 115v60Hz is standard. 4-Channel Pulse Output. One channel for fuel mgt system & one for tank monitor X 2 hoses. Includes a second field conduit. Qty of 2 of 4-Channel Pulse Output for 3x24 Active-4. One channel for fuel mgt system & one for tank monitor X 2 hoses. Includes a second field conduit. Fleet Card Option (available for certain models only) Junction Box in Lower Hydraulic Area. Standard is wiring terminal strip in electronics head. 2nd field conduit. One 3/4" field conduit is standard. If Pulse Output is selected (P or P2) a second conduit is automatically added at no charge. 3-Phase Motor Contactor (suction units) or Sub Pump Relay (remotes). Hose Retractor (internal); (low hose models only) - Hose Clamp is NOT Included. White lower doors. Red is standard. Blue lower doors. Red is standard Black lower doors. Red is standard. Green lower doors. Red is standard. Yellow lower doors. Red is standard. Above are standard Bennett colors. For other color lower door single color or special screening, provide artwork. Brushed Stainless lower door. Red is standard. Brushed Stainless End Panel. Black painted is standard. Stainless "All Panels" Option Combines SD & SE & Cover Assembly (top) for low hose models only. "Super Stainless" Option. Combines AP plus hinged upper doors & grade panel area. Strainer for remote dispensers. Internal paper filter cartridge is standard. Strainer with cloth sack for remote or suction dispensers. Internal paper filter cartridge is standard for remotes; Strainer is standard for suction models. Spin-On Filter for remote models. Internal paper filter cartridge is standard. Includes 10micron standard filter & filter adapter. For long Balance vapor nozzles or Healy 400 nozzle, order nozzle lever extension kit #111303 as a field installed item Custom Graphics, One Time Charge Per Color Special Paint, One Time Charge per Color New Graphics Design Services, Rate per Hour (1-Hr Minimum) Notes
Note 3 Note 3 Note 4
Note 2 Note 2 Note 1 & 2
CG SP GD Note 1: Note 2: Note 3: Note 4:
Standard 10micron spin on is compatible with E85 Filtration Note: 3x24 "Active-4" Remote models are standard with spin-on filters. No other options available. PetroVend Systems require PetroVend's # 20-4268 Voltage to Current Sense Converter. Available for models that have only one display per side (see configuration drawing keys booklet for complete list)
Bennett Pump Company / Bennett Commercial Pump Company Model List: GoPump-C-Low Options - 010110 Replaces: July 1, 2008
3000 Series Model List
6
Effective January 1, 2010
GoPump Commercial (Volume Only) Electronic Dispenser High Hose Style Cabinets
Nozzle Boot Mount Low Hose Models Nominal Flow Rate in GPM (note 1) Base Drawing # Fleet Card Option Available? yes yes yes yes no yes no no no yes no no yes no yes yes no yes no no no yes no Suction / Remote Pumping Units Product Inlets Cabinet Style Hose Outlets Drawing Key 3 4 3 4 8 9 10 14 15 16 14 15 16 34 1 or 2 Sided
Description
Single Single Single-HD Single-HD 1Prod Dual 1Prod Dual 1Prod Dual 2Prod Dual 2Prod Dual 2Prod Dual 2Prod Dual-HD 2Prod Dual-HD 2Prod Dual-HD Active-4
3711SNS-3 -4 3711HNS-3 -4
Suction Pumps - High Hose Style Cabinets Suction 1 1 High 2 Side Standard Suction 1 1 High 1 Front Standard Suction 1 1 High 2 Side Heavy Duty Suction 1 1 High 1 Front Heavy Duty 1 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 4 High High High High High High High High High High 2 2 1 2 1 2 2 1 2 2 Side Front Front Side Front Front Side Front Front Front Heavy Duty Heavy Duty Heavy Duty Standard Standard Standard Heavy Duty Heavy Duty Heavy Duty Heavy Duty
10 10 15 15
P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3
3712SNS-8 Suction -9 Suction -10 Suction 3722SNS-14 -15 -16 3722HNS-14 -15 -16 Suction Suction Suction Suction Suction Suction
15 & 10 (Note 2) P1388s2v3 15 & 10 (Note 2) P1388s2v3 15 & 10 (Note 2) P1388s2v3 10 10 10 15 15 15 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3
3724SNS-34 Suction
15 & 10 (Note 2) P1388s2v3
Single Single 1Prod Dual 1Prod Dual 1Prod Dual 2Prod Dual 2Prod Dual 2Prod Dual Active-4
Remote Dispensers - High Hose Style Cabinets Side 19 3711SNR-19 Remote 1 1 High 2 -20 Remote 1 1 High 1 Front 20 3712SNR-24 Remote -25 Remote -26 Remote 3722SNR-30 Remote -31 Remote -32 Remote 3724SNR-36 Remote 1 1 1 2 2 2 2 2 2 2 2 2 2 4 High High High High High High High 2 2 1 2 1 2 2 Side Front Front Side Front Front Front 24 25 26 30 31 32 36
15 15 15 15 15 15 15 15
P1389s1v1 P1389s1v1 P1389s1v2 P1389s1v2 P1389s1v2 P1389s1v1 P1389s1v1 P1389s1v1
15 & 13 (Note 2) P1387s2v4
Master and Satellite Note: Satellite internal piping option is not available for high hose GoPump Cabinets. Use the high hose Little Squirt or high hose Big Squirt Master, or use a low hose GoPump instead.
Note 1: Flow rates are nominal rates under test conditions. Actual rates will vary subject to installation conditions, hanging hardware used, and submerged pump used if applicable. Rates are in U.S. gallons per minute. For liters per minute multiply gpm X 3.7854. Note 2: One Product, Dual Suction Flow Rate: First GPM number is rate with only 1 hose flowing. Second GPM number is rate from each hose with both hoses flowing simultaneously. Note 3: For freight and title transfer information, refer to your Distributor Policy & Procedure Manual.
Model List: GoPump-C-High 3000 - 070108
3000 Series Model List
7
Effective January 1, 2010
GoPump Commercial (Volume Only) Electronic Dispenser High Hose Style Cabinets OPTIONS
Add desired option(s) to end of Cabinet model number, for example, 3711SNS-3-V-P Option V E85 IG L M 11550 23060 23050 380 P P2 F J 2C R S SC WD BD KD GD YD OD SD SE AP SS VC STR SK SO BV Descriptions Solenoid valve option. For 1-Product,1-Hose Suction or 2-Product, 2-Hose Suction. Standard on other models. E85 Compatibility Imperial Gallon measurement. US Gallons is standard. Liter measurement. US Gallons is standard. Mechanical Calibration. Electronic calibration is standard. 115v 50Hz. 115v60Hz is standard. 230v60Hz. 115v60Hz is standard. 230v50Hz. 115v60Hz is standard. 380v50Hz 3-Phase. 115v60Hz is standard. 4-Channel Pulse Output. One channel for fuel mgt system & one for tank monitor X 2 hoses. Includes a second field conduit Qty of 2 of 4-Channel Pulse Output for 3x24 Active-4. One channel for fuel mgt system & one for tank monitor X 2 hoses. Includes a second field conduit Fleet Card Option (available for certain models only) Junction Box in Lower Hydraulic Area. Standard is wiring terminal strip in electronics head. 2nd field conduit. One 3/4" field conduit is standard. If Pulse Output is selected (P or P2) a second conduit is automatically added at no charge. 3-Phase Motor Contactor (suction units) or Sub Pump Relay (remotes) Intercom Speaker Intercom Speaker w/ Call Button White lower doors. Red is standard. Blue lower doors. Red is standard Black lower doors. Red is standard Green lower doors. Red is standard. Yellow lower doors. Red is standard. Above are standard Bennett colors. For Other color lower door single color or special screening, provide artwork. Brushed Stainless lower door. Red is standard. Brushed Stainless End Panel. Black painted is standard. Stainless "All Panels" Option Combines SD & SE & Electronic Cover Assembly. Does NOT include electronic front & rear doors. "Super Stainless" Option. Combines AP plus hinged upper doors, grade panel area, inside columns, top trough, & small top cover. Valance/Canopy Kit (field installed) Strainer for remote dispensers. Internal paper filter cartridge is standard. Strainer with cloth sack for remote or suction dispensers. Internal paper filter cartridge is standard for remotes; Strainer is standard for suction models. Spin-On Filter for remote models. Internal paper filter cartridge is standard. Includes 10micron standard filter & filter adapter. Balance Vapor Option. Includes Co-Ax hose outlet & internal vapor piping For long Balance vapor nozzles or Healy 400 nozzle, order nozzle lever extension kit #111303 as a field installed item Custom Graphics, One Time Charge Per Color Special Paint, One Time Charge per Color New Graphics Design Services, Rate per Hour (1-Hr Minimum) Standard 10micron spin on is compatible with E85 Filtration Note: 3x24 "Active-4" Remote models are standard with spin-on filters. No other options available. PetroVend Systems require PetroVend's # 20-4268 Voltage to Current Sense Converter. Available for models that have only one display per side (see configuration drawing keys booklet for complete list) Notes
Note 3 Note 3 Note 4
Note 2 Note 2 Note 1 & 2
CG SP GD Note 1: Note 2: Note 3: Note 4:
Bennett Pump Company / Bennett Commercial Pump Company Model List: GoPump-C-High Options - 010110 Replaces: July 1, 2008
3000 Series Model List
8
Effective January 1, 2010
Little Squirt Commercial (Volume Only) Electronic Dispenser Low Hose Style Cabinets & Companion Satellites/Little Squirt Satellite & LPS Economy Satellites
Nozzle Boot Mount Low Hose Models Nominal Flow Rate in GPM (note 1) Base Drawing # Fleet Card Option Available? yes yes yes yes no yes no no yes no yes no no no no no Suction / Remote Pumping Units Product Inlets
Cabinet Style
Hose Outlets
Suction Pumps - Low Hose Style Cabinets Single Master Single Master 3711LMS-41 Suction -42 Suction 1 1 1 1 Low Low 2 1 Side Front 2 Heavy Duty 41 2 Heavy Duty 42 40 40 P1385s1v1 P1385s1v1
Remote Dispensers - Low Hose Style Cabinets Single Master Single Master 1Prod Dual Master 1Prod Dual Master 1Prod Dual Master 2Prod Dual Master 2Prod Dual Master 2Prod Dual Master Mast/Sat Combo Single Satellite 3K Dual Satellite 3K Dual Satellite 3K Single Satellite Dual Satellite 3711LMR-37 Remote -38 Remote 3712LMR-45 Remote -46 Remote -47 Remote 3722LMR-51 Remote -52 Remote -53 Remote 3722LCR-57 Remote 3811LSR-59 Remote 3822LSR-61 Remote -62 Remote LPS40-1-65 Remote LPS40-2-65 Remote 1 1 1 1 1 2 2 2 2 1 2 2 1 2 1 1 2 2 2 2 2 2 2 1 2 2 1 2 Low Low Low Low Low Low Low Low Low Low Low Low Low Low 2 1 2 2 1 2 2 1 2 1 2 1 1 2 Side Front Side Front Front Side Front Front Front Front Front Front Either Either 37 38 45 46 47 51 52 53 57 59 61 62 65 65 40 40 40 40 40 40 40 40 40 40 40 40 40 40 P1384s1v1 P1384s1v1 P1384s1v2 P1384s1v2 P1384s1v2 P1384s1v1 P1384s1v1 P1384s1v1 P1384s2v3 P1385s2v4 P1385s2v4 P1385s2v4 P0349 P0349
Note 1: Flow rates are nominal rates under test conditions. Actual rates will vary subject to installation conditions, hanging hardware used, and submerged pump used if applicable. Rates are in U.S. gallons per minute. For liters per minute multiply gpm X 3.7854. Note 2: One Product, Dual Suction Flow Rate: First GPM number is rate with only 1 hose flowing. Second GPM number is rate from each hose with both hoses flowing simultaneously. Note 3: For freight and title transfer information, refer to your Distributor Policy & Procedure Manual.
Model List: Little Squirt-C-Low 3000 - 070108
3000 Series Model List
1 or 2 Sided
Drawing Key
Description
9
Effective January 1, 2010
Little Squirt Commercial (Volume Only) Electronic Dispenser Low Hose Style Cabinets & Satellites OPTIONS
Add desired option(s) to end of Cabinet model number, for example, 3711LMR-37-P Option M SL V IG L 11550 23060 23050 380 P F J 2C R RD WD BD KD GD YD OD SD SE AP SS CG SP GD Note 1: Note 2: Descriptions Satellite Internal Piping (remote models only- Add "M" in place of "R", for example 3711LMR becomes 3711LMM) Satellite-in-use Light for Master hose (remotes only) Solenoid valve option for suction pumps. Imperial Gallon measurement. US Gallons is standard. Liter measurement. US Gallons is standard. 115v 50Hz. 115v60Hz is standard. 230v60Hz. 115v60Hz is standard. 230v50Hz. 115v60Hz is standard. 380v50Hz 3-Phase. 115v60Hz is standard. 4-Channel Pulse Output. One channel for fuel mgt system & one for tank monitor X 2 hoses. Includes a second field conduit Fleet Card Option (available for certain models only) Junction Box in Lower Hydraulic Area. Standard is wiring terminal strip in electronics head. 2nd field conduit. One 3/4" field conduit is standard. If Pulse Output is selected (P or P2) a second conduit is automatically added at no charge. 3-Phase Motor Contactor (suction units) or Sub Pump Relay (remotes) Red lower doors. Green is standard. White Lower doors. Green is standard. Blue lower doors. Green is standard Black lower doors. Green is standard. Green lower doors. Green is standard. Yellow lower doors. Green is standard. Above are standard Bennett colors. For Other color lower door single color or special screening, provide artwork. Brushed Stainless lower door. Green is standard. Brushed Stainless End Panel. Black painted is standard. Stainless "All Panels" Option Combines SD & SE & Cover Assembly (top) for low hose models only. "Super Stainless" Option. Combines AP plus hinged upper doors & grade panel area. Custom Graphics, One Time Charge Per Color Special Paint, One Time Charge per Color New Graphics Design Services, Rate per Hour (1-Hr Minimum) Notes
Note 1 Note 2
PetroVend Systems require PetroVend's # 20-4268 Voltage to Current Sense Converter. Available for models that have only one display per side (see configuration drawing keys booklet for complete list)
Bennett Pump Company / Bennett Commercial Pump Company Model List: Little Squirt-C-Low Options - 010110 Replaces: July 1, 2008
3000 Series Model List
10
Effective January 1, 2010
Big Squirt Commercial (Volume Only) Electronic Dispenser Low Hose Style Cabinets & Companion Satellites/Big Squirt Satellite & LPS Economy Satellites
Nozzle Boot Mount Nominal Flow Rate in GPM (note 1) Low Hose Models Base Drawing # Fleet Card Option Available? yes yes no yes no no yes no yes no no no no no Suction / Remote Product Inlets
Cabinet Style
Hose Outlets
Suction Pumps - Low Hose Style Cabinets Big Squirt Dispensers are Available Only in Remote Dispenser Versions - For Suction Pumps, refer to Little Squirt Models Lists Remote Dispensers - Low Hose Style Cabinets Single Master Single Master 1Prod Dual Master 1Prod Dual Master 1Prod Dual Master 2Prod Dual Master 2Prod Dual Master 2Prod Dual Master Mast/Sat Combo Single Satellite 3K Dual Satellite 3K Dual Satellite 3K Single Satellite Dual Satellite 3711BMR-37 -38 3712BMR-45 -46 -47 3722BMR-51 -52 -53 3722BCR-57 3811BSR-59 3822BSR-61 -62 LPS60-1-65 LPS60-2-65 Remote Remote Remote Remote Remote Remote Remote Remote Remote Remote Remote Remote Remote Remote 1 1 1 1 1 2 2 2 2 1 2 2 1 2 1 1 2 2 2 2 2 2 2 1 2 2 1 2 Low Low Low Low Low Low Low Low Low Low Low Low Low Low 2 1 2 2 1 2 2 1 2 1 2 1 1 2 Side Front Side Front Front Side Front Front Front Front Front Front Either Either 37 38 45 46 47 51 52 53 57 59 61 62 65 65 60 60 60 60 60 60 60 60 60 60 60 60 60 60 P1384s1v1 P1384s1v1 P1384s1v2 P1384s1v2 P1384s1v2 P1384s1v1 P1384s1v1 P1384s1v1 P1384s2v3 P1385s2v4 P1385s2v4 P1385s2v4 P0349 P0349
Note 1: Flow rates are nominal rates under test conditions. Actual rates will vary subject to installation conditions, hanging hardware used, and submerged pump used if applicable. Rates are in U.S. gallons per minute. For liters per minute multiply gpm X 3.7854. Flow rates shown for remotes are for master & satellite combined simultaneous flow. Note 2: One Product, Dual Suction Flow Rate: First GPM number is rate with only 1 hose flowing. Second GPM number is rate from each hose with both hoses flowing simultaneously. Note 3: For freight and title transfer information, refer to your Distributor Policy & Procedure Manual.
Model List: Big Squirt-C-Low 3000 - 070108
3000 Series Model List
1 or 2 Sided
Drawing Key
Description
11
Effective January 1, 2010
Big Squirt Commercial (Volume Only) Electronic Dispenser Low Hose Style Cabinets & Satellites OPTIONS
Add desired option(s) to end of Cabinet model number, for example, 3711BMR-37-P Option M SL IG L 11550 23060 23050 380 P F J 2C R WD RD BD KD GD YD OD SD SE AP SS CG SP GD Note 1: Note 2: Descriptions Satellite Internal Piping (remote models only- Add "M" in place of "R", for example 3711BMR becomes 3711BMM) Satellite-in-use Light for Master hose (remotes only) Imperial Gallon measurement. US Gallons is standard. Liter measurement. US Gallons is standard. 115v 50Hz. 115v60Hz is standard. 230v60Hz. 115v60Hz is standard. 230v50Hz. 115v60Hz is standard. 380v50Hz 3-Phase. 115v60Hz is standard. 4-Channel Pulse Output. One channel for fuel mgt system & one for tank monitor X 2 hoses. Includes a second field conduit Fleet Card Option (available for certain models only) Junction Box in Lower Hydraulic Area. Standard is wiring terminal strip in electronics head. 2nd field conduit. One 3/4" field conduit is standard. If Pulse Output is selected (P or P2) a second conduit is automatically added at no charge. 3-Phase Motor Contactor (suction units) or Sub Pump Relay (remotes) White lower doors. Green is standard. Red lower doors. Green is standard. Blue lower doors. Green is standard Black lower doors. Green is standard. Green lower doors. Green is standard. Yellow lower doors. Green is standard. Above are standard Bennett colors. For Other color lower door single color or special screening, provide artwork. Brushed Stainless lower door. Green is standard. Brushed Stainless End Panel. Black painted is standard. Stainless "All Panels" Option Combines SD & SE & Cover Assembly (top) for low hose models only. "Super Stainless" Option. Combines AP plus hinged upper doors & grade panel area. Custom Graphics, One Time Charge Per Color Special Paint, One Time Charge per Color New Graphics Design Services, Rate per Hour (1-Hr Minimum) PetroVend Systems require PetroVend's # 20-4268 Voltage to Current Sense Converter. Available for models that have only one display per side (see configuration drawing keys booklet for complete list) Notes
Note 1 Note 2
Bennett Pump Company / Bennett Commercial Pump Company Model List: Big Squirt -C-Low Options - 010110 Replaces: July 1, 2008
3000 Series Model List
12
Effective January 1, 2010
Big Squirt Commercial (Volume Only) Electronic Dispenser & Satellites High Hose Style Cabinets
Nozzle Boot Mount Nominal Flow Rate in GPM (note 1) Low Hose Models Fleet Card Option Available? yes yes no yes no yes no no no no Suction / Remote Base Drawing # P1384s1v1 P1384s1v2 P1384s1v2 P1384s1v1 P1384s1v1 P1384s2v3 P1384s2v4 P1385s2v4 P1385s2v4 P1385s2v4 Product Inlets
Cabinet Style
Hose Outlets
Single Master 1Prod Dual Master 1Prod Dual Master 2Prod Dual Master 2Prod Dual Master Mast/Sat Combo Mast/Sat Dual Combo Single Satellite 3K Dual Satellite 3K Dual Satellite 3K
Remote Dispensers - High Hose Style Cabinets 3711BMR-40 Remote 1 1 High 1 Front 3712BMR-49 -50 3722BMR-55 -56 3722BCR-58 3744BCM-56.1 3811BSR-60 3822BSR-63 -64 Remote Remote Remote Remote Remote Remote Remote Remote Remote 1 1 2 2 2 4 1 2 2 2 2 2 2 2 4 1 2 2 High High High High High High High High High 2 1 2 1 2 2 1 2 1 Front Front Front Front Front Front Front Front Front
1 or 2 Sided
Drawing Key 40 49 50 55 56 58 56.1 60 63 64
Description
60 60 60 60 60 60 60 60 60 60
Note 1: Flow rates are nominal rates under test conditions. Actual rates will vary subject to installation conditions, hanging hardware used, and submerged pump used if applicable. Rates are in U.S. gallons per minute. For liters per minute multiply gpm X 3.7854. Flow rates shown for remotes are for master & satellite combined simultaneous flow. Note 2: Low hose style satellite can be used with high hose masters. See Low hose Model list. Note 3: Remote low hose models are available as a "master" with a satellite outlet pipe installed. Add "M" to model number in lieu of "R", for example: 3711BMR-39 becomes 3711BMM-39. Note 4: For freight and title transfer information, refer to your Distributor Policy & Procedure Manual.
Model List: Big Squirt-C-High 3000 - 070108
3000 Series Model List
13
Effective January 1, 2010
Big Squirt Commercial (Volume Only) Electronic Dispenser & Satellites High Hose Style Cabinets OPTIONS
Add desired option(s) to end of Cabinet model number, for example, 3711BMR-39-P Option M SL IG L 11550 23060 23050 380 P F J 2C R S SC WD RD BD KD GD YD OD SD SE AP SS VC CG SP GD Note 1: Note 2: Descriptions Satellite Internal Piping (remote models only- Add "M" in place of "R", for example 3711BMR becomes 3711BMM) Satellite-in-use Light for Master hose (remotes only) Imperial Gallon measurement. US Gallons is standard. Liter measurement. US Gallons is standard. 115v 50Hz. 115v60Hz is standard. 230v60Hz. 115v60Hz is standard. 230v50Hz. 115v60Hz is standard. 380v50Hz 3-Phase. 115v60Hz is standard. 4-Channel Pulse Output. One channel for fuel mgt system & one for tank monitor X 2 hoses. Includes a second field conduit Fleet Card Option (available for certain models only) Junction Box in Lower Hydraulic Area. Standard is wiring terminal strip in electronics head. 2nd field conduit. One 3/4" field conduit is standard. If Pulse Output is selected (P or P2) a second conduit is automatically added at no charge. 3-Phase Motor Contactor (suction units) or Sub Pump Relay (remotes) Intercom Speaker Intercom Speaker w/Call Button White lower doors. Green is standard. Red lower doors. Green is standard. Blue lower doors. Green is standard Black lower doors. Green is standard. Green lower doors. Green is standard. Yellow lower doors. Green is standard. Above are standard Bennett colors. For Other color lower door single color or special screening, provide artwork. Brushed Stainless lower door. Green is standard. Brushed Stainless End Panel. Black painted is standard. Stainless "All Panels" Option Combines SD & SE & Electronic Cover Assembly. Does NOT include electronic front & rear doors. "Super Stainless" Option. Combines AP plus hinged upper doors & grade panel area, inside columns, top trough, & small top cover. Valance/Canopy Kit (Field Installed) Custom Graphics, One Time Charge Per Color Special Paint, One Time Charge per Color New Graphics Design Services, Rate per Hour (1-Hr Minimum) Notes
Note 1 Note 2
PetroVend Systems require PetroVend's # 20-4268 Voltage to Current Sense Converter. Available for models that have only one display per side (see configuration drawing keys booklet for complete list)
Bennett Pump Company / Bennett Commercial Pump Company Model List: Big Squirt-C-High Options - 010110 Replaces: July 1, 2008
3000 Series Model List
14
Effective January 1, 2010
Heritage Retail Mechanical Dispensers Low Hose Style Cabinets
Nozzle Boot Mount Nominal Flow Rate in GPM (note 1) Suction / Remote CamAc Model VR10 Computer 1 or 2 Sided Base Drawing # P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1389s1v1 P1389s1v2 P1389s1v1 P0349 P0349 Pumping Units Product Inlets Electric Reset Model CR10 Computer Cabinet Style Hose Outlets Drawing Key
Description
Single Single -HD 1Prod Dual
3511SNS-66 3611SNS-66 Suction 3511HNS-66 3611HNS-66 Suction 3512SNS-5 3612SNS-5 Suction
Suction Pumps 1 1 Low 2 1 1 Low 2 1 2 Low 2
Side Standard 66 Side Heavy Duty 66 Side Heavy Duty
15 24
5 23&13 (note 2) P1388s2v3 15 24 23 23 23
2Prod Dual 3522SNS-11 3622SNS-11 Suction 2 2 Low 2 2Prod Dual - HD 3522HNS-11 3622HNS-11 Suction 2 2 Low 2 Remote Dispensers Single 3511SNR-68 3611SNR-68 Remote 1 1 Low 2 1Prod Dual 2Prod Dual Single Satellite Dual Satellite 3512SNR-21 3612SNR-21 Remote 3522SNR-27 3622SNR-27 Remote LPS40-1-65 LPS40-1-65 LPS40-2-65 LPS40-2-65 Remote Remote 1 2 1 2 2 2 1 2 Low Low Low Low 2 2
Side Standard 11 Side Heavy Duty 11 Side Side Side 68 21 27 65 65
1 Either 2 Either
Note 1: Flow rates are nominal rates under test conditions. Actual rates will vary subject to installation conditions, hanging hardware used, and submerged pump used if applicable. Rates are in U.S. gallons per minute. For liters per minute multiple gpm X 3.7854. Note 2: One Product, Dual Suction Flow Rate: First GPM number is rate with only 1 hose flowing. Second GPM number is rate from each hose with both hoses flowing simultaneously. Note 3: For freight and title transfer information, refer to your Distributor Policy & Procedure Manual. VR10 Mechanical Computers from Veeder-Root are standard. The VR10 maximum price per gallon is $5.999 with a maximum sale of $999.99. A kit is available from Veeder-Root to allow a price setting of up to $7.999.
Model List: Heritage Low 3000 - 110609
3000 Series Model List
15
Effective January 1, 2010
Heritage Retail Mechanical Dispensers Low Hose Style Cabinets OPTIONS
Add desired option(s) to end of Cabinet model number, for example, 3512SNS-5-E85-SD-SE Option V E85 IG L 11550 23060 23050 380 Pulsers J 2C HR WD BD KD GD YD OD SD SE AP SS STR SK SO NK CG SP GD Note 1: Descriptions Solenoid Valve Option. For 1-Product, 1 Hose Suction or 2-Product, 2 Hose Suction. Standard on other models. E85 Compatibility Imperial Gallon measurement. US Gallons is standard. Liter measurement. US Gallons is standard. 115v 50Hz. 115v60Hz is standard. 230v60Hz. 115v60Hz is standard. 230v50Hz. 115v60Hz is standard. 380v50Hz 3-Phase. 115v60Hz is standard. Pulsers are not available from Bennett for the VR10 Computers. Field Install "Western"-style pulsers from OPW/PetroVend Junction Box in Lower Hydraulic Area. Standard is wiring terminal strip in electronics head. 2nd field conduit. One 3/4" field conduit is standard. If Pulse Output is selected (P or P2) a second conduit is automatically added at no charge. Hose Retractor (internal); (low hose models only) - Hose Clamp is NOT included. White lower doors. Green is standard. Blue lower doors. Green is standard Black lower doors. Green is standard. Green lower doors. Green is standard. Yellow lower doors. Green is standard. Above are standard Bennett colors. For Other color lower door single color or special screening, provide artwork. Brushed Stainless lower door. Green is standard. Brushed Stainless End Panel. Black painted is standard. Stainless "All Panels" Option Combines SD & SE & Electronic Cover Assembly. Does NOT include electronic front & rear doors. "Super Stainless" Option. Combines AP plus hinged upper doors & grade panel area, inside columns, top trough, & small top cover. Strainer for remote dispensers. Internal paper filter cartridge is standard. Strainer with cloth sack for remote of suction dispensers. Internal paper filter cartridge is standard from remotes; Strainer is standard for suction models. Spin-On Filter for remote models. Internal paper filter cartridge is standard. Includes 10 micron standard filter & filter adaptor. Nozzle Kit (Field installed) for Balance Vapor Nozzle (Kit #A601801) Custom Graphics, One Time Charge Per Color Special Paint, One Time Charge per Color New Graphics Design Services, Rate per Hour (1-Hr Minimum) Standard 10micron spin on is compatible with E85. Notes
Note 1
Bennett Pump Company / Bennett Commercial Pump Company Model List: Heritage Low Options - 070108 Replaces: November 19, 2007
3000 Series Model List
16
Effective January 1, 2010
GoPump Retail (Money & Volume) Electronic Dispensers Low Hose Style Cabinets
Nozzle Boot Mount Nominal Flow Rate in GPM (note 1) Low Hose Models 1 or 2 Sided Fleet Card Option Available? yes yes yes yes no yes no no no yes no no yes no yes yes no yes no no no yes no no no no no no Suction / Remote Base Drawing # P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1389s1v1 P1389s1v1 P1389s1v2 P1389s1v2 P1389s1v2 P1389s1v1 P1389s1v1 P1389s1v1 P1387s2v4 P1385s2v4 P1385s2v4 P1385s2v4 P0349 P0349 Pumping Units Product Inlets Cabinet Style Hose Outlets Drawing Key 1 2 1 2 5 6 7 11 12 13 11 12 13 33 17 18 21 22 23 27 28 29 35 59 61 62 65 65
Description
Single Single Single-HD Single-HD 1Prod Dual 1Prod Dual 1Prod Dual 2Prod Dual 2Prod Dual 2Prod Dual 2Prod Dual-HD 2Prod Dual-HD 2Prod Dual-HD Active-4 Single Single 1Prod Dual 1Prod Dual 1Prod Dual 2Prod Dual 2Prod Dual 2Prod Dual Active-4 Single Satellite 3K Dual Satellite 3K Dual Satellite 3K Single Satellite Dual Satellite
3811SNS-1 -2 3811HNS-1 -2
Suction Suction Suction Suction
1 1 1 1 1 1 1 2 2 2 2 2 2 2
1 1 1 1 2 2 2 2 2 2 2 2 2 4
Suction Pumps Low 2 Side Standard Low 1 Front Standard Low 2 Side Heavy Duty Low 1 Front Heavy Duty Low Low Low Low Low Low Low Low Low 2 2 1 2 1 2 2 1 2 Side Heavy Duty Front Heavy Duty Front Heavy Duty Side Front Front Side Front Front Standard Standard Standard Heavy Duty Heavy Duty Heavy Duty
15 15 24 24 23&12 (Note 2) 23&12 (Note 2) 23&12 (Note 2) 15 15 15 24 24 24 23&12 (Note 2) 23 23 23 23 23 23 23 23 23&12 (Note 2)
3812SNS-5 Suction -6 Suction -7 Suction 3822SNS-11 -12 -13 3822HNS-11 -12 -13 Suction Suction Suction Suction Suction Suction
3824SNS-33 Suction
3811SNR-17 Remote 1 -18 Remote 1 3812SNR-21 Remote 1 -22 Remote 1 -23 Remote 1 3822SNR-27 Remote 2 -28 Remote 2 -29 Remote 2 3824SNR-35 Remote 2 3811LSR-59 Remote 1 3822LSR-61 Remote 2 -62 Remote 2 LPS40-1-65 Remote 1 LPS40-2-65 Remote 2
Low 2 Front Heavy Duty Remote Dispensers 1 Low 2 Side 1 Low 1 Front 2 2 2 2 2 2 Low Low Low Low Low Low Low Low Low Low Low Low 2 2 1 2 1 2 2 1 2 1 1 2 Side Front Front Side Front Front Front Front Front Front Either Either
4 1 2 2 1 2
Retail GoPump communication with external control devices can be performed with one of the following methods (only one method can be used): 1. Current Loop High Level Fuel Control Protocol Interface (direct to the dispenser or via a Model 515 Bennett Pump Controller. 2. RS485 Dispenser Interface 3. Pulse Output (requires pulse output option - see options Model list) Remote price setting from external control device is allowed only through the Current Loop Interface. TMS "mechanical" consoles should not be used with Bennett "electronic" dispensers; use TMS "electronic" console instead. Note 1: Flow rates are nominal rates under test conditions. Actual rates will vary subject to installation conditions, hanging hardware used, and submerged pump used if applicable. Rates are in U.S. gallons per minute. For liters per minute multiply gpm X 3.7854. Note 2: One Product, Dual Suction Flow Rate: First GPM number is rate with only 1 hose flowing. Second GPM number is rate from each hose with both hoses flowing simultaneously. Note 3: Field Installed Consumer Payment Systems such as eFueling, E J Ward, MultiForce, Trak, etc - Add the "F" option Factory installed VeriFone MX760 Secure PumpPAY credit/debit reader payment system - Add VF1 or VF2 option VF1 or VF2 option requires 515 Pump Controller and I/C Box. Note 4: For freight and title transfer information, refer to your Distributor Policy & Procedure Manual.
Model List: GoPump-R-Low 3000 - 070108
3000 Series Model List
17
Effective January 1, 2010
GoPump Retail (Money & Volume) Electronic Dispensers Low Hose Style Cabinets OPTIONS
Add desired option(s) to end of Cabinet model number, for example, 3512SNS-5-E85-SD-SE Option SL V E85 IG L M 11550 23060 23050 380 LP P P2 F VF1 VF2 J 2C R HR WD BD KD GD YD OD SD SE AP SS STR SK SO Descriptions Satellite-in-use Light for Master Hose (Remotes only) Solenoid Valve Option. For 1-Product, 1 Hose Suction or 2-Product, 2 Hose Suction. Standard on other models. E85 Compatibility Imperial Gallon measurement. US Gallons is standard. Liter measurement. US Gallons is standard. Mechanical Calibration. Electronic calibration is standard. 115v 50Hz. 115v60Hz is standard. 230v60Hz. 115v60Hz is standard. 230v50Hz. 115v60Hz is standard. 380v50Hz 3-Phase. 115v60Hz is standard. Local Preset. Cannot combine with "F" Option 4-Channel Pulse Output. One channel for fuel mgt system & one for tank monitor X 2 hoses. Includes a second field conduit Qty of 2 of 4-Channel Pulse Output for 3x24 Active -4. One channel for fuel mgt system & one for tank monitor X 2 hoses. Includes a second field conduit Fleet Card Option (available for certain models only) VeriFone MX760 Debit/Credit Reader (one side) VeriFone MX760 Debit/Credit Reader (two sided) Junction Box in Lower Hydraulic Area. Standard is wiring terminal strip in electronics head. 2nd field conduit. One 3/4" field conduit is standard. If Pulse Output is selected (P or P2) a second conduit is automatically added at no charge. 3-Phase Motor Contactor (suction units) or Sub Pump Relay (remotes) Hose Retractor (internal); (low hose models only) - Hose Clamp is NOT included. White lower doors. Green is standard. Blue lower doors. Green is standard Black lower doors. Green is standard. Green lower doors. Green is standard. Yellow lower doors. Green is standard. Above are standard Bennett colors. For Other color lower door single color or special screening, provide artwork. Brushed Stainless lower door. Green is standard. Brushed Stainless End Panel. Black painted is standard. Stainless "All Panels" Option Combines SD & SE & Electronic Cover Assembly. Does NOT include electronic front & rear doors. "Super Stainless" Option. Combines AP plus hinged upper doors & grade panel area, inside columns, top trough, & small top cover. Strainer for remote dispensers. Internal paper filter cartridge is standard. Strainer with cloth sack for remote of suction dispensers. Internal paper filter cartridge is standard from remotes; Strainer is standard for suction models. Spin-On Filter for remote models. Internal paper filter cartridge is standard. Includes 10 micron standard filter & filter adaptor. For long Balance vapor nozzles or Healy 400 nozzle, order nozzle lever extension kit #111303 as a field installed item Custom Graphics, One Time Charge Per Color Special Paint, One Time Charge per Color New Graphics Design Services, Rate per Hour (1-Hr Minimum) Notes
Note 3 Note 3 Note 4 Note 4 Note 4
Note 2 Note 2 Note 1 & 2
CG SP GD Note 1: Note 2: Note 3: Note 4:
Standard 10micron spin on is compatible with E85 Filtration Note: 3x24 "Active-4" Remote models are standard with spin-on filters. No other options available. PetroVend Systems require PetroVend's # 20-4268 Voltage to Current Sense Converter. Available for models that have only one display per side (see configuration drawing keys booklet for complete list)
Bennett Pump Company / Bennett Commercial Pump Company Model List: GoPump-R-Low Options - 010110 Replaces: July 1, 2008
3000 Series Model List
18
Effective January 1, 2010
GoPump Retail (Money & Volume Readout) Electronic Dispensers High Hose Style Cabinets
Nozzle Boot Mount Nominal Flow Rate in GPM (note 1) Low Hose Models Product Inlets 1 or 2 Sided Fleet Card Option Available? yes yes yes yes no yes no no no yes no no yes no yes yes no yes no no no yes no Suction / Remote Base Drawing # P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1388s2v3 P1389s1v1 P1389s1v1 P1389s1v2 P1389s1v2 P1389s1v2 P1389s1v1 P1389s1v1 P1389s1v1 Pumping Units Cabinet Style Hose Outlets Drawing Key
Description
Single Single Single-HD Single-HD 1Prod Dual 1Prod Dual 1Prod Dual 2Prod Dual 2Prod Dual 2Prod Dual 2Prod Dual-HD 2Prod Dual-HD 2Prod Dual-HD Active-4
3811SNS-3 -4 3811HNS-3 -4
Suction Pumps - High Hose Style Cabinets Suction 1 1 High 2 Side Standard 3 Suction 1 1 High 1 Front Standard 4 Suction 1 1 High 2 Side Heavy Duty 3 Suction 1 1 High 1 Front Heavy Duty 4 2 High 2 High 2 High 2 2 2 2 2 2 High High High High High High 2 2 1 2 1 2 2 1 2 2 Side Front Front Side Front Front Side Front Front Front Heavy Duty Heavy Duty Heavy Duty Standard Standard Standard Heavy Duty Heavy Duty Heavy Duty Heavy Duty
10 10 15 15
3812SNS-8 Suction 1 -9 Suction 1 -10 Suction 1 3822SNS-14 -15 -16 3822HNS-14 -15 -16 Suction Suction Suction Suction Suction Suction 2 2 2 2 2 2
8 15 & 10 (Note 2) P1388s2v3 9 15 & 10 (Note 2) P1388s2v3 10 15 & 10 (Note 2) P1388s2v3 14 15 16 14 15 16 10 10 10 15 15 15
3824SNS-34 Suction 2
4 High
34 15 & 10 (Note 2) P1388s2v3
Single Single 1Prod Dual 1Prod Dual 1Prod Dual 2Prod Dual 2Prod Dual 2Prod Dual Active-4
Remote Dispensers - High Hose Style Cabinets 19 3811SNR-19 Remote 1 1 High 2 Side -20 Remote 1 1 High 1 Front 20 3812SNR-24 Remote 1 -25 Remote 1 -26 Remote 1 3822SNR-30 Remote 2 -31 Remote 2 -32 Remote 2 3824SNR-36 Remote 2 2 High 2 High 2 High 2 High 2 High 2 High 4 High 2 2 1 2 1 2 2 Side Front Front Side Front Front Front 24 25 26 30 31 32
15 15 15 15 15 15 15 15
36 15 & 13 (Note 2) P1387s2v4
Retail GoPump communication with external control devices can be performed with one of the following methods (only one method can be used): 1. Current Loop High Level Fuel Control Protocol Interface (direct to the dispenser or via a Model 515 Bennett Pump Controller. 2. RS485 Dispenser Interface. 3. Pulse Output (requires pulse output option - see options model list). Remote price setting from external control device is allowed only through the Current Loop Interface. TMS "mechanical" consoles should not be used with Bennett "electronic" dispensers; use TMS "electronic" console instead.
Master and Satellite Note: Satellite internal piping option is not available for high hose GoPump cabinets. Use the high hose Little Squirt or high hose Big Squirt Master, or use a low hose GoPump instead. Note 1: Flow rates are nominal rates under test conditions. Actual rates will vary subject to installation conditions, hanging hardware used, and submerged pump used if applicable. Rates are in U.S. gallons per minute. For liters per minute multiply gpm X 3.7854. Note 2: One Product, Dual Suction Flow Rate: First GPM number is rate with only 1 hose flowing. Second GPM number is rate from each hose with both hoses flowing simultaneously. Note 3: Field Installed Consumer Payment Systems such as eFueling, E J Ward, MultiForce, Trak, etc - Add the "F" option Factory installed VeriFone MX760 Secure PumpPAY credit/debit reader payment system - Add VF1 or VF2 option VF1 or VF2 option requires 515 Pump Controller and I/C Box. Note 4: For freight and title transfer information, refer to your Distributor Policy & Procedure Manual.
Price List: GoPump-R-High 3000 - 070108
3000 Series Model List
19
Effective January 1, 2010
GoPump Retail (Money & Volume Readout) Electronic Dispensers High Hose Style Cabinets OPTIONS
Option V E85 IG L M 11550 23060 23050 380 LP P P2 F VF1 VF2 J 2C R S SC WD BD KD GD YD OD SD SE AP SS VC STR SK SO BV Add desired option(s) to end of Cabinet model number, for example, 3811SNS-3-V-P Descriptions Solenoid valve option. For 1-Product,1-Hose Suction or 2-Product, 2-Hose Suction. Standard on other models. E85 Compatibility Imperial Gallon measurement. US Gallons is standard. Liter measurement. US Gallons is standard. Mechanical Calibration. Electronic calibration is standard. 115v 50Hz. 115v60Hz is standard. 230v60Hz. 115v60Hz is standard. 230v50Hz. 115v60Hz is standard. 380v50Hz 3-Phase. 115v60Hz is standard. Local Preset. Cannot combine with "F" option. 4-Channel Pulse Output. One channel for fuel mgt system & one for tank monitor X 2 hoses. Includes a second field conduit Qty of 2 of 4-Channel Pulse Output for 3x24 Active-4. One channel for fuel mgt system & one for tank monitor X 2 hoses. Includes a second field conduit Fleet Card Option (available for certain models only) VeriFone MX760 Debit/Credit Card Reader (One side) VeriFone MX760 Debit/Credit Card Reader (Two sides) Junction Box in Lower Hydraulic Area. Standard is wiring terminal strip in electronics head. 2nd field conduit. One 3/4" field conduit is standard. If Pulse Output is selected (P or P2) a second conduit is automatically added at no charge. 3-Phase Motor Contactor (suction units) or Sub Pump Relay (remotes) Intercom Speaker Intercom Speaker w/ Call Button White lower doors. Red is standard. Blue lower doors. Red is standard Black lower doors. Red is standard Green lower doors. Red is standard. Yellow lower doors. Red is standard. Above are standard Bennett colors. For Other color lower door single color or special screening, provide artwork. Brushed Stainless lower door. Red is standard. Brushed Stainless End Panel. Black painted is standard. Stainless "All Panels" Option Combines SD & SE & Electronic Cover Assembly. Does NOT include electronic front & rear doors. "Super Stainless" Option. Combines AP plus hinged upper doors, grade panel area, inside columns, top trough, & small top cover. Valance/Canopy Kit (field installed) Strainer for remote dispensers. Internal paper filter cartridge is standard. Strainer with cloth sack for remote or suction dispensers. Internal paper filter cartridge is standard for remotes; Strainer is standard for suction models. Spin-On Filter for remote models. Internal paper filter cartridge is standard. Includes 10micron standard filter & filter adapter. Balance Vapor Option. Includes Co-Ax hose outlet & internal vapor piping. For long Balance vapor nozzles or Healy 400 nozzle, order nozzle lever extension kit #111303 as a field installed item Custom Graphics, One Time Charge Per Color Special Paint, One Time Charge per Color New Graphics Design Services, Rate per Hour (1-Hr Minimum) Notes
Note 3 Note 3 Note 4 Note 4 Note 4
Note 2 Note 2 Note 1 & 2
CG SP GD Note 1: Note 2: Note 3: Note 4:
Standard 10micron spin on is compatible with E85 Filtration Note: 3x24 "Active-4" Remote models are standard with spin-on filters. No other options available. PetroVend Systems require PetroVend's # 20-4268 Voltage to Current Sense Converter. Available for models that have only one display per side (see configuration drawing keys booklet for complete list)
Bennett Pump Company / Bennett Commercial Pump Company Model List: GoPump-R-High Options - 010110 Replaces: July 1, 2008
3000 Series Model List
20
Effective January 1, 2010
Little Squirt Retail (Money & Volume) Electronic Dispenser Low Hose Style Cabinets & Companion Satellites/Little Squirt Satellite & LPS Economy Satellites
Nozzle Boot Mount Nominal Flow Rate in GPM (note 1) Low Hose Models Product Inlets Hose Outlets Fleet Card Option Available? yes yes yes yes no yes no no yes no yes no no no no no Suction / Remote Base Drawing # P1385s1v1 P1385s1v1 P1384s1v1 P1384s1v1 P1384s1v2 P1384s1v2 P1384s1v2 P1384s1v1 P1384s1v1 P1384s1v1 P1384s2v3 P1385s2v4 P1385s2v4 P1385s2v4 P0349 P0349 Pumping Units
Cabinet Style
Single Master Single Master Single Master Single Master 1Prod Dual Master 1Prod Dual Master 1Prod Dual Master 2Prod Dual Master 2Prod Dual Master 2Prod Dual Master Mast/Sat Combo Single Satellite 3K Dual Satellite 3K Dual Satellite 3K Single Satellite Dual Satellite
Suction Pumps - Low Hose Style Cabinets 3811LMS-41 Suction 1 1 Low 2 Side 2 Heavy Duty 41 -42 Suction 1 1 Low 1 Front 2 Heavy Duty 42 Remote Dispensers - Low Hose Style Cabinets 3811LMR-37 Remote 1 1 Low 2 Side 37 -38 Remote 1 1 Low 1 Front 38 3812LMR-45 Remote 1 -46 Remote 1 -47 Remote 1 3822LMR-51 Remote 2 -52 Remote 2 -53 Remote 2 3822LCR-57 Remote 2 3811LSR-59 Remote 1 3822LSR-61 Remote 2 -62 Remote 2 LPS40-1-65 Remote 1 LPS40-2-65 Remote 2 2 2 2 2 2 2 2 1 2 2 1 2 Low Low Low Low Low Low Low Low Low Low Low Low 2 2 1 2 2 1 2 1 2 1 1 2 Side Front Front Side Front Front Front Front Front Front Either Either 45 46 47 51 52 53 57 59 61 62 65 65
1 or 2 Sided
Drawing Key
Description
40 40 40 40 40 40 40 40 40 40 40 40 40 40 40 40
Retail Little Squirt communication with external control devices can be performed with one of the following methods (only one method can be used): 1. Current Loop High Level Fuel Control Protocol Interface (direct to the dispenser or via a Model 515 Bennett Pump Controller. 2. RS485 Dispenser Interface 3. Pulse Output (requires pulse output option - see options Model list) Remote price setting from external control device is allowed only through the Current Loop Interface. TMS "mechanical" consoles should not be used with Bennett "electronic" dispensers; use TMS "electronic" console instead. Note 1: Flow rates are nominal rates under test conditions. Actual rates will vary subject to installation conditions, hanging hardware used, and submerged pump used if applicable. Rates are in U.S. gallons per minute. For liters per minute multiply gpm X 3.7854. Flow rates shown for remotes are for master & satellite combined simultaneous flow. Note 2: Remote low hose models are available as a "master" with a satellite outlet pipe installed. Add "M" to model number in lieu of "R", for example: 3811LMR-37 becomes 3811LMM-37. Note 3: For freight and title transfer information, refer to your Distributor Policy & Procedure Manual. Note 4: Field Installed Consumer Payment Systems such as eFueling, E J Ward, MultiForce, Trak, etc - Add the "F" option Factory installed VeriFone MX760 Secure PumpPAY credit/debit reader payment system - Add VF1 or VF2 option VF1 or VF2 option requires 515 Pump Controller and I/C Box.
Model List: Little Squirt-R-Low 3000 - 070108
3000 Series Model List
21
Effective January 1, 2010
Little Squirt Retail (Money & Volume) Electronic Dispenser Low Hose Style Cabinets & Satellites OPTIONS
Add desired option(s) to end of cabinet model number, for example, 3811LMR-37-P Option M SL V IG L 11550 23060 23050 380 LP P F VF1 VF2 J 2C R WD RD BD KD GD YD OD SD SE AP SS CG SP GD Note 1: Note 2: Descriptions Satellite Internal Piping (remote models only- Add "M" in place of "R", for example 3711LMR becomes 3711LMM) Satellite-in-use Light for Master hose (remotes only) Solenoid valve option for suction pumps. Imperial Gallon measurement. US Gallons is standard. Liter measurement. US Gallons is standard. 115v 50Hz. 115v60Hz is standard. 230v60Hz. 115v60Hz is standard. 230v50Hz. 115v60Hz is standard. 380v50Hz 3-Phase. 115v60Hz is standard. Local Preset. Cannot combine with "F" option. 4-Channel Pulse Output. One channel for fuel mgt system & one for tank monitor X 2 hoses. Includes a second field conduit Fleet Card Option (available for certain models only) VeriFone MX760 Debit/Credit Card Reader (One side) VeriFone MX760 Debit/Credit Card Reader (Two sides) Junction Box in Lower Hydraulic Area. Standard is wiring terminal strip in electronics head. 2nd field conduit. One 3/4" field conduit is standard. If Pulse Output is selected (P or P2) a second conduit is automatically added at no charge. 3-Phase Motor Contactor (suction units) or Sub Pump Relay (remotes) White lower doors. Green is standard. Red lower doors. Green is standard. Blue lower doors. Green is standard Black lower doors. Green is standard Green lower doors. Green is standard. Yellow lower doors. Green is standard. Above are standard Bennett colors. For Other color lower door single color or special screening, provide artwork. Brushed Stainless lower door. Green is standard. Brushed Stainless End Panel. Black painted is standard. Stainless "All Panels" Option Combines SD & SE & Cover Assembly (top) for low hose models only. "Super Stainless" Option. Combines AP plus hinged upper doors & grade panel area. Custom Graphics, One Time Charge Per Color Special Paint, One Time Charge per Color New Graphics Design Services, Rate per Hour (1-Hr Minimum) PetroVend Systems require PetroVend's # 20-4268 Voltage to Current Sense Converter. Available for models that have only one display per side (see configuration drawing keys booklet for complete list) Note 1 Note 2 Note 2 Note 2 Notes
Bennett Pump Company / Bennett Commercial Pump Company Model List: Little Squirt-R-Low Options - 010110 Replaces: July 1, 2008
3000 Series Model List
22
Effective January 1, 2010
Big Squirt Retail (Money & Volume) Electronic Dispenser Low Hose Style Cabinets & Companion Satellites/Big Squirt Satellite & LPS Economy Satellites
Nozzle Boot Mount Nominal Flow Rate in GPM (note 1) Low Hose Models Fleet Card Option Available? yes yes no yes no no yes no yes no no no no no Suction / Remote Base Drawing # P1384s1v1 P1384s1v1 P1384s1v2 P1384s1v2 P1384s1v2 P1384s1v1 P1384s1v1 P1384s1v1 P1384s2v3 P1385s2v4 P1385s2v4 P1385s2v4 P0349 P0349 Product Inlets
Cabinet Style
Hose Outlets
Single Master Single Master 1Prod Dual Master 1Prod Dual Master 1Prod Dual Master 2Prod Dual Master 2Prod Dual Master 2Prod Dual Master Mast/Sat Combo Single Satellite 3K Dual Satellite 3K Dual Satellite 3K Single Satellite Dual Satellite
Remote Dispensers - Low Hose Style Cabinets 3811BMR-37 Remote 1 1 Low 2 Side 37 -38 Remote 1 1 Low 1 Front 38 3812BMR-45 Remote -46 Remote -47 Remote 3822BMR-51 Remote -52 Remote -53 Remote 3822BCR-57 Remote 3811BSR-59 Remote 3822BSR-61 Remote -62 Remote LPS60-1-65 Remote LPS60-2-65 Remote 1 1 1 2 2 2 2 1 2 2 1 2 2 2 2 2 2 2 2 1 2 2 1 2 Low Low Low Low Low Low Low Low Low Low Low Low 2 2 1 2 2 1 2 1 2 1 1 2 Side Front Front Side Front Front Front Front Front Front Either Either 45 46 47 51 52 53 57 59 61 62 65 65
1 or 2 Sided
Description
Drawing Key
60 60 60 60 60 60 60 60 60 60 60 60 60 60
Retail Big Squirt communication with external control devices can be performed with one of the following methods (only one method can be used): 1. Current Loop High Level Fuel Control Protocol Interface (direct to the dispenser or via a Model 515 Bennett Pump Controller. 2. RS485 Dispenser Interface 3. Pulse Output (requires pulse output option - see options Model list) Remote price setting from external control device is allowed only through the Current Loop Interface. TMS "mechanical" consoles should not be used with Bennett "electronic" dispensers; use TMS "electronic" console instead. Note 1: Flow rates are nominal rates under test conditions. Actual rates will vary subject to installation conditions, hanging hardware used, and submerged pump used if applicable. Rates are in U.S. gallons per minute. For liters per minute multiply gpm X 3.7854. Flow rates shown for remotes are for master & satellite combined simultaneous flow. Note 2: Remote low hose models are available as a "master" with a satellite outlet pipe installed. Add "M" to model number in lieu of "R", for example: 3811BMR-37 becomes 3811BMM-37 Note 3: For freight and title transfer information, refer to your Distributor Policy & Procedure Manual Note 4: Field Installed Consumer Payment Systems such as eFueling, E J Ward, MultiForce, Trak, etc - Add the "F" option Factory installed VeriFone MX760 Secure PumpPAY credit/debit reader payment system - Add VF1 or VF2 option VF1 or VF2 option requires 515 Pump Controller and I/C Box.
Model List: Big Squirt-R-Low 3000 - 070108
3000 Series Model List
23
Effective January 1, 2010
Big Squirt Retail (Money & Volume) Electronic Dispenser Low Hose Style Cabinets & Satellites OPTIONS
Add desired option(s) to end of cabinet model number, for example, 3811LMR-37-P Option M SL IG L 11550 23060 23050 380 LP P F VF1 VF2 J 2C R WD RD BD KD GD YD OD SD SE AP SS CG SP GD Note 1: Note 2: Descriptions Satellite Internal Piping (remote models only- Add "M" in place of "R", for example 3811BMR becomes 3811BMM) Satellite-in-use Light for Master hose (remotes only) Imperial Gallon measurement. US Gallons is standard. Liter measurement. US Gallons is standard. 115v 50Hz. 115v60Hz is standard. 230v60Hz. 115v60Hz is standard. 230v50Hz. 115v60Hz is standard. 380v50Hz 3-Phase. 115v60Hz is standard. Local Preset. Cannot combine with "F" option. 4-Channel Pulse Output. One channel for fuel mgt system & one for tank monitor X 2 hoses. Includes a second field conduit Fleet Card Option (available for certain models only) VeriFone MX760 Debit/Credit Card Reader (One side) VeriFone MX760 Debit/Credit Card Reader (Two sides) Junction Box in Lower Hydraulic Area. Standard is wiring terminal strip in electronics head. 2nd field conduit. One 3/4" field conduit is standard. If Pulse Output is selected (P or P2) a second conduit is automatically added at no charge. 3-Phase Motor Contactor (suction units) or Sub Pump Relay (remotes) White lower doors. Green is standard. Red lower doors. Green is standard. Blue lower doors. Green is standard Black lower doors. Green is standard Green lower doors. Green is standard. Yellow lower doors. Green is standard. Above are standard Bennett colors. For Other color lower door single color or special screening, provide artwork. Brushed Stainless lower door. Green is standard. Brushed Stainless End Panel. Black painted is standard. Stainless "All Panels" Option Combines SD & SE & Cover Assembly (top) for low hose models only. "Super Stainless" Option. Combines AP plus hinged upper doors & grade panel area. Custom Graphics, One Time Charge Per Color Special Paint, One Time Charge per Color New Graphics Design Services, Rate per Hour (1-Hr Minimum) PetroVend Systems require PetroVend's # 20-4268 Voltage to Current Sense Converter. Available for models that have only one display per side (see configuration drawing keys booklet for complete list) Note 1 Note 2 Note 2 Note 2 Notes
Bennett Pump Company / Bennett Commercial Pump Company Model List: Big Squirt-R-Low Options - 010110 Replaces: July 1, 2008
3000 Series Model List
24
Effective January 1, 2010
Big Squirt Retail (Money & Gallon) Electronic Dispenser & Satellites High Hose Style Cabinets
Nozzle Boot Mount Nominal Flow Rate in GPM (note 1) Low Hose Models Fleet Card or VeriFone Option Available? (note 5) yes yes no yes no yes no no no no Suction / Remote Product Inlets 1 or 2 Sided Base Drawing # P1384s1v1 P1384s1v2 P1384s1v2 P1384s1v1 P1384s1v1 P1384s2v3 P1384s2v4 P1385s2v4 P1385s2v4 P1385s2v4 Cabinet Style Hose Outlets Drawing Key
Description
Single Master 1Prod Dual Master 1Prod Dual Master 2Prod Dual Master 2Prod Dual Master Mast/Sat Combo Mast/Sat Dual Combo Single Satellite 3K Dual Satellite 3K Dual Satellite 3K
Remote Dispensers - High Hose Style Cabinets 3811BMR-40 Remote 1 1 High 1 Front 40 3812BMR-49 Remote -50 Remote 3822BMR-55 Remote -56 Remote 3822BCR-58 Remote 3844BCM-56-1 Remote 3811BSR-60 Remote 3822BSR-63 Remote -64 Remote 1 1 2 2 2 4 1 2 2 2 2 2 2 2 4 1 2 2 High High High High High High High High High 2 1 2 1 2 2 1 2 1 Front Front Front Front Front Front Front Front Front 49 50 55 56 58 56-1 60 63 64
60 60 60 60 60 60 60 60 60 60
Retail Big Squirt communication with external control devices can be performed with one of the following methods (only one method can be used): 1. Current Loop High Level Fuel Control Protocol Interface (direct to the dispenser or via a Model 515 Bennett Pump Controller. 2. RS485 Dispenser Interface. 3. Pulse Output (requires pulse output option - see options Model list). Remote price setting from external c